Current Transducers

Ohio Semitronics manufactures DC current transducers, as well as both absolute average and true RMS measuring AC Current transducers in ranges from 5 milliamps through 300,000 amps. All are available in a variety of form factors. Standard outputs include: 0-1 mA, 4-20mA, 0-10Vdc and 0-5Vdc. Customized input ranges and output formats are available on request.



AC Current Transducers


AC Current transducers are available to measure absolute average or true RMS AC currents in ranges from 5 milliamps through 300,000 amps. Transducers are available as single or three-phase with wired inputs for external current transformers or may incorporate the CT’s into the same package, in either solid core or split core (clamp-on) packages. DIN Rail-mounted packaging is also available.


Available outputs include 0-1mA, 4-20mA, 0-10Vdc and 0-5Vdc with customized input ranges and output formats available on request. OSI achieves these by using a variety of measurement technologies, including Hall Effect, open and closed loop circuits, as well as flux gate and Rogowski techniques.



AC Input Output Connection/Aperture Product Family
RMS 0-40,000A
depending on model
0-1mAdc, 4-20mAdc,
0-5Vdc,0-10Vdc
Direct, 0.6", 1.25", 2.5",
3.0", 6.5", 10.5",
14.0", 21.5"
CTS, CTCR, ACTR, 3CTR, CTRS,
MCTR, DCTR, CT8
AVERAGE 0-2,000A
depending on model
0-1mAdc,4-20mAdc,
0-5Vdc,0-10Vdc
Direct, 0.6", 1.25",
2.5", 3.0"
CTS, ACT, 3ACT, CTC, CTD,
MCT5, SCT, DCT
TRANSFORMERS 0-6,000A
depending on model
0.1A, 1.0A, 5.0A,
0.333V, 1.0V, 5V
0.75" thru 11" x 3.82" MCCT, CTY, CTI,
FSCCT, LCCT
ROGOWSKI
COILS
0-300,000A
depending on model
0-1mAdc, 0-20mAdc,
4-20mAdc, 0-5Vdc,
0-10Vdc
6.5", 10.5", 14.0", 21.5" MFC150, RPS, FCA,
CTRS


Shop Now
AC Current Transducer, DIN rail-mounted, Manufactured by Ohio Semitronics
DC Current Transducer Manufactured by Ohio Semitronics

DC Current Transducers


OSI DC current transducers allow the customer to choose to measure DC current via a direct connection, conductor through-hole or clamp on technique. DIN Rail-mounted packaging is also available.


Ranges are available from 100 milliamps through 40,000 amps with a selection of outputs including 0-1mA, 4-20mA, 0-10Vdc and 0-5Vdc. Customized input ranges and output formats are available on request.



DC (AC) Input Output Connection/Aperture Product Family
OPEN LOOP
CURRENT SENSING
0-40,000A
depending on model
0-1mAdc, 4-20mAdc,
0-5Vdc, 0-10Vdc
0.375" thru 13" x 13" CTL, CTA, CTG, CTH,
CTLC, ISC, CTLP
CLOSED LOOP
CURRENT SENSING
0-500A 100mA 1.0", 1.25", 1.6" CTF, CTFB, CTFG
FLUX GATE 0-600A 0-300mA 0.59", 1.18" UFG


Shop Now