Ohio Semitronics now has an ANAB-accredited process that enables calibration and certification of electrical measurements to the 17025 standard for frequencies well above the 40th harmonic of either 50 or 60 Hz.The calibration may also include additive DC offset voltages.

Calibration and certification of electrical measurements at 45-65 Hz has been common; however, the US Department of Energy recently required measurement of non-fundamental frequencies up to the 40th harmonic for several industries.This also aligns with other governing bodies’ recent changes. Unfortunately, there has not been an available means to calibrate and certify above 45-65 Hz.


Parameter Frequency Range Measurement Range Limitations




Fundamental AC Voltage 16-850 Hz 0.1 - 1,008 Volts AC
Additive DC Voltage Offset NA 0.1 - 504 Volts DC Up to 50% of range
Additive AC Voltage Harmonics 16 - 6,000 Hz 0.1 - 302 Volts AC Up to 30% of range




Fundamental AC Current 40-850 Hz 0.01 - 80 Amps AC
Additive DC Offset Current NA 0.01 - 10 Amps DC Up to 50% of range
Additive AC Current Harmonics 16 - 6,000 Hz 0.01 - 200 Amps AC Up to 30% of range




Current to Voltage Phase Offset 16 - 6,000 Hz (-180 to +180)°




Power 16 - 6,000 Hz 1 Watt to 200 kW




Energy 16 - 6,000 Hz 10 Wh to 200 kWh


OSI offers 17025 Certificates of Calibration for its own measurement devices.